An aired cored inductor is connected in series with a switch and d.c. source. The switch is closed and left for some time. Explain why a spark is observed across the switch contacts when the switch is reopened.
An aired cored inductor is connected in series with a switch and d.c. source. The switch is closed and left for some time. Explain why a spark is observed across the switch contacts when the switch is reopened. (03marks)
When the switch is opened, the falling current causes a change in the magnetic flux linking the inductor coil.
A change in the magnetic flux linking the coil, induce a large e.m.f in the circuit and leads to high the electric field intensity between the contact points causing ionization of gases.
When the oppositely charged ions collide, a spark is produced.