(iii)	Explain why the current in the primary coil of a transformer increases when the secondary is connected to the load.

(iii) Explain why the current in the primary coil of a transformer increases when the secondary is connected to the load.

Explain why the current in the primary coil of a transformer increases when the secondary is connected to the load.

When load is connected to the secondary winding, a current flows in it. The current flows in such a direction as to reduce the back e.m.f in primary coil, hence the current increase.